SERVICE & OPERATING INSTRUCTIONS
Spring Retaining Bolt
Bushing O-Ring
Clamping Pin O-Ring
Clamping Pin
Bushing
Piston O-RIng
Spring
Housing
Piston
Top Face O-Ring
Mounting Screw
Parts for Turbo Version
Mounting Screw Cover
Cover Plate Mounting Screws
Cover Plate
Cover Plate Mounting Screws O-Ring
Cover Plate O-Rings
• Min. operating air pressure: 75 PSI • Min. recommended air line: ø.250" O.D. • Air must be filtered to a maximum particle size of 10μm, dried and lubricated • Use of dust covers is recommended for chucks that are not in use • Close all air connections when chuck is not in use
• For vertical wall mounting, chuck orientation should be such that the clamping pins are horizontal • For long term storage, spray rust preventative into air ports and cycle the chuck 4-5 times • For more in-depth service instructions please consult BIG KAISER Engineering Dept.
Visit www.us.BIGKAISER.com for Additional Instructions