Unilock Modular Workholding System Vol. 2

SERVICE & OPERATING INSTRUCTIONS

Spring Retaining Bolt

Bushing O-Ring

Clamping Pin O-Ring

Clamping Pin

Bushing

Piston O-RIng

Spring

Housing

Piston

Top Face O-Ring

Mounting Screw

Parts for Turbo Version

Mounting Screw Cover

Cover Plate Mounting Screws

Cover Plate

Cover Plate Mounting Screws O-Ring

Cover Plate O-Rings

• Min. operating air pressure: 75 PSI • Min. recommended air line: ø.250" O.D. • Air must be filtered to a maximum particle size of 10μm, dried and lubricated • Use of dust covers is recommended for chucks that are not in use • Close all air connections when chuck is not in use

• For vertical wall mounting, chuck orientation should be such that the clamping pins are horizontal • For long term storage, spray rust preventative into air ports and cycle the chuck 4-5 times • For more in-depth service instructions please consult BIG KAISER Engineering Dept.

Visit www.us.BIGKAISER.com for Additional Instructions