BIG DAISHOWA High Performance Tooling Solutions Vol 5

MEASURING INSTRUMENTS

POINT MASTER (PMC SERIES) Instantaneous detection with LED and beep. LED flashes to notify low battery life while measuring workpieces.

NEW Product

For use with conductive workpieces and machine tools

LED flashes to indicate that battery life is low

360°

Notifies using 360º LED light

Notifies via buzzer

LIVE

Battery Alarm

LED

Buzzer

Conductivity

Cylindrical Shank Type

L 1

L

2.894

1.496

ø6mm Over-Travel

Z

Buzzer

Over-Travel

LED Ring

Catalog Number

Weight (lbs.)

øDs

L

L 1

Battery

6mm

“S”at End of Model

PMC-20R PMC-20RS PMC-32R PMC-32RS

20mm 3.937

2.362

LR1x2

.7

32mm 3.937

2.362

LR1x2

1.1

• ST38-6P stylus is included; models with an S at the end of the model number include ø6 cylindrical ST38-6X6 stylus • Batteries not included; use batteries commercially available on the market • Cannot be used with non-conductive workpieces and machines with ceramic bearings, use POINT MASTER

BBT Shank Type

L

2.894

Buzzer

1.496

BBT No.

ø6mm Over-Travel

Z

Over-Travel

R

LED Ring

SPINDLE SYSTEM DUAL CONTACT

6mm

“S”at End of Model

Catalog Number

Weight (lbs.)

L

Battery

Pullstud bolts with a center through hole cannot be used. In the case of machines that require a hole on the pullstud bolts due to the coolant nozzle, please contact BIG DAISHOWA.

BBT40-PMC-130R BBT40-PMC-130RS BBT50-PMC-160R BBT40-PMC-160RS

5.118

LR1x2

2.6

ACCESSORIES

6.300 LR03x2

8.8

• ST38-6P stylus is included; models with an S at the end of the model number include ø6 cylindrical ST38-6X6 stylus • Batteries not included; use batteries commercially available on the market • Cannot be used with non-conductive workpieces and machines with ceramic bearings. Use POINT MASTER

STYLUS PG. 600

Specifications

Probe Repeatability

±1μm (.00004")

Over-Travel

XY ±12mm Z 5mm (XY ±.472" Z .197")

Cannot be used with non-conductive workpieces or machines with ceramic bearings. Use POINT MASTER PRO.

Measuring Pressure

XY 0.8N

Z 3.8N

• The specifications above are values when the standard accessory stylus is used • The measured pressure is the value when the stroke exceeds the specied limit by .2mm